Tooling Set-Up and Alignment Procedures

Good and Not Good Registry Markers

Function

  • The Registry Marker has a raised circle with the letters "N " and "G " located within, raised to different levels (see Fig.2).
  • At the bottom of the die stroke, if a circle and a "G " are stamped in your metal panel, the die is set properly (see Fig.1).
  • If a circle and "NG " appears, the hit is too hard (see Fig.1).
  • If no mark appears, the hit is too light (see Fig.1).

Location in the Die

The Registry Marker is mounted in the same die shoe as the installation head and is positioned over the part panel that is to receive the PierceForm Nut (see Fig.3).The Registry Marker should be located as close to the Head as possible.

Setting

The proper shut height of the "Good " Registry Marker is 76.07mm (2.995")(see Fig 3).Shut height dimension does not include retainer plate thickness.

Mounting in the Die

The Registry Marker incorporates a heavy-duty ball lock feature to facilitate mounting in the die.(Ball lock retainer must be provided by customer.)

Additional Information

Inch Registry Markers are available. Heavy-duty ball lock Registry Markers also available: Inch MS-26-30-H, Metric MSM-26-30-HD

Alignment Procedures

MHN Round Pierce Nut installation heads may be mounted in the die by either of two methods: Direct Layout or Die Layout.

Direct Layout Method

  • Install die button retainer by direct layout or with template.
  • Insert alignment die button in retainer.
  • Invert die set (so die button retainer is on top).
  • Set base, back-up plate, and plunger in head position.
  • Lower die shoe (with retainer) so plunger enters die button. Plunger and die button must be equivalent sizes.
  • Transfer base mounting holes to die (with punch).
  • Repeat steps above for all heads in die.
  • Drill and tap mounting holes for screws.
  • Loosely mount base and back-up plate in each head location.
  • Replace mating die shoe.
  • Lower die shoe (with retainer) so plunger enters die button.
  • Tighten base mounting screws.
  • Repeat steps above for each head in die.
  • Remove mating die shoe; transfer dowel holes. Drill as required for reaming.
  • Ream for press fit for dowel pins.
  • Locate and machine clearance holes for shank and spring.
  • Install head in each head location. Follow plant die tryout procedures; follow Multifastener ram setting procedures in this manual.

Die Layout Method

  • Install die button retainer by direct layout or with template.
  • Insert alignment die button in retainer.
  • Loosely mount base, back-up plate, and plunger in each head location by die layout procedure.
  • Lower die shoe with retainer so plunger properly enters die button.
  • Tighten base mounting screws.
  • Repeat steps above for each head in die.
  • Remove mating die shoe; transfer dowel holes. Drill as required for reaming.
  • Ream for press fit for dowel pins.
  • Locate and machine clearance holes for shank and spring.
  • Install head in each head location. Follow plant die tryout procedures; follow ram setting procedures in this manual.

 

 

Home  |  Site Map  |  Search

FabriSteel A Division of Whitesell International Corporation
22100 Trolley Industrial Drive
Taylor, MI  48180-1872
(313) 299-8540

 

This page last modified 06/08/07 .
All information © 2007 Whitesell International Corporation

Site Use Policy

Go To Top