Part Design Guidelines
CS Series PierceForm Studs are property class 9.8
automatically installed, system-fed fasteners for installation
in pre-pierced holes.
Designed for thick metal applications, CS Series PierceForm
Studs make a consistent mechanical attachment which provides a
secure, permanent installation; standard stud lengths are 16,
20, 25 and 30mm; standard end configuration is the header point.
All CS Series PierceForm Studs can be heat treated to property
class 10.9 if your application requires. This can be
accomplished using a shorter barrel on the stud.
CS Series PierceForm Studs may be installed in almost any
panel material, of almost any shape, and in almost any
multiple-pattern configuration, within the constraints shown
below. However - if you have a unique application not covered
here, give us a call. We will help work out a solution with you.
Application in
Special Materials
For HSLA, stainless
steel, aluminum, and/or plastic material, consult your
representative for application assistance.
Select Proper Stud
Select according to
tables found on PierceForm CS Stud
specifications sheet.
Using Two Sheets of Metal
Total panel
thickness not to exceed 90%of recommended thickness for CS series PierceForm
Stud metal range. For other panel materials, contact your
representative.
Sealing Applications
Sealing is attained
as an integral feature of the installation process by adding and
adhesive to the barrel. Consult your
representative for further details.
Critical Applications
When extreme
torque, stress, or environmental requirements exist, consult your
representative for application assistance.
Accuracy of
Location
In multiple stud
installations the location of one stud to another will be within a
diametral tolerance of 0.4mm (0.015in.).
When a Forming
Operation Follows a Stud Operation
Do not form part closer than 10 mm (0.39 in.) after stud is
installed, as shown. For CS Series PierceForm Studs, part
material formed into the clinch must not be disturbed. For
closer spacing requirements, consult your representative.

Stud Edge to Panel Edge Distance
Studs must not be
installed closer to the edge of a panel than twice the thickness of
the metal panel, as shown.

Minimum Stud
Spacing (With Standard Head Installation Tooling, Retainers May
Require Alteration)
NOTE: Closer
stud-to-stud distances may be achieved using altered standard and/or
special tooling. Consult your representative.

Stud to Flange
Distances (With Standard Installation Tooling)
Closer
stud-to-flange distances may be achieved using altered standard
and/or special tooling. Consult your representative.

| Stud Flow |
C |
D |
| Stud Flow A |
26.5mm |
62.0mm Max |
| Stud Flow B |
20.00mm |
62.0mm Mas |
|