Maintenance
Head
Assemblies do not require continuous lubrication. However, careful
maintenance means longer product life and hours of trouble-free
operation. Internal lubrication must be an integral part of air
supply system. It is recommended that a thorough internal cleaning
and lubrication be completed between 80,000 and 90,000 cycles.
External lubrication should occur every 25,000 cycles.
The head should be
removed from the die and disassembled, as outlined in “Assembly/
Disassembly.” Clean all grease and metal particles from parts.
Coat parts with a lithium soap base grease Molykote BRZ-5 or
equivalent and reassemble the head. The lubricant is available from
the following sources:
FabriSteel
22100
Trolley Industrial Drive
Taylor,
Michigan 48180
Dow
Corning Corporation
South
Saginaw Road
Midland, Michigan 48641
Catalog #8500-26
|