Part Design Guidelines
PierceForm CP Studs
are property class 9.8 and act as their own punch to become rigidly
and permanently attached to a metal panel within the same die used
to form the part and stud, thereby offering many advantages over
conventional fasteners. PierceForm CP Studs make a consistent mechanical attachment
which provides a secure, permanent installation; standard stud
lengths are 16, 20, 25 and 30mm; standard end configurations are the
header and ISO short dog point. PierceForm CP Studs may be installed in almost any panel
material, of almost any shape, and in almost any multiple-pattern
configuration, within the constraints shown below. However, if you
have a unique application not covered here, give us a call. We will
help work out a solution with you.
Application in
Special Materials
For HSLA, stainless
steel, aluminum, and/or plastic material, consult your
representative.
Select Proper Stud
Select according to
tables found on PierceForm CP Stud specifications sheet.
Simulpiercing Two Sheets of Metal
(PierceForm Studs
Only).
Total panel
thickness not to exceed 90%of recommended thickness for PierceForm
Stud metal range. For other panel materials, contact your
representative.
Sealing Applications
Sealing is attained
as an integral feature of the installation process. Consult your
representative for further details.
Critical Applications
When extreme
torque, stress, or environmental requirements exist, consult your
representative prior to specifying PierceForm CP Studs.
Accuracy of
Location
(PierceForm Studs Only)
In multiple stud
installations the location of one stud to another will be within a
diametral tolerance of 0.4mm.
When a Forming
Operation Follows a Stud Operation
Do not form part
closer than 10.0mm after PierceForm CP Stud is installed, as shown. For closer spacing requirements, consult your
representative.

Stud Edge to Panel Edge Distance
Studs must not be
installed closer to the edge of a panel than twice the thickness of
the metal panel, as shown.

Minimum Stud
Spacing (With Standard Head Installation Tooling, Retainers May
Require Alteration)
NOTE: Closer
stud-to-stud distances may be achieved using altered standard and/or
special tooling. Consult your representative.

Stud to Flange
Distances (With Standard Installation Tooling)
Closer
stud-to-flange distances may be achieved using altered standard
and/or special tooling. Consult your representative.

| Stud Size |
A |
B |
| M5, 6, 8, 10 |
26.5mm |
32.5mm |
|